Model
|
6705
|
6710
|
6720
|
6730
|
6740
|
|
INPUT
|
|
Phase
|
1 Phase
|
|
Voltage
|
115/230Vac ± 15%
|
230Vac ± 15%
|
|
Frequency
|
47-63Hz
|
|
OUTPUT
|
|
Power rating
|
500VA
|
1000VA
|
2000VA
|
3000VA
|
4000VA
|
|
Max. Current(r.m.s)
|
0-150V
|
4.2A
|
8.4A
|
16.8A
|
25.2A
|
33.6A
|
|
0-300V
|
2.1A
|
4.2A
|
8.4A
|
12.6A
|
16.8A
|
|
Max. Current(peak)
|
0-150V
|
16.8A
|
33.6A
|
67.2A
|
100.8A
|
134.4A
|
|
0-300V
|
8.4A
|
16.8A
|
33.6A
|
50.4A
|
67.2A
|
|
Option 0-600V
|
|
Max. Current(r.m.s)
|
0-300V
|
2.1A
|
4.2A
|
8.4A
|
12.6A
|
16.8A
|
|
0-600V
|
1.05A
|
2.1A
|
4.2A
|
6.3A
|
8.4A
|
|
Max. Current(peak)
|
0-300V
|
8.4A
|
16.8A
|
33.6A
|
50.4A
|
67.2A
|
|
0-600V
|
4.2A
|
8.4A
|
16.8A
|
25.2A
|
33.6A
|
|
Phase
|
1Phase / 2W
|
|
THD(Total Harmonic Distortation)
|
<=0.5% at 45-500Hz (Resistive Load)
|
|
Crest Factor
|
>= 4
|
|
Line Regulation
|
0.1% max for a ± 10% line change.
|
|
Load Regulation
|
<=0.5% (Resistive Load)
|
|
Response Time
|
< 100µS
|
|
SETTING
|
|
Voltage
|
Range
|
0-300V, 150/300V Auto or
|
|
0-600V,300/600V Auto(Option 0-600V)
|
|
Resolution
|
0.1V
|
|
Accuracy
|
±(0.5%+2 counts)
|
|
Frequency
|
Range
|
45-500Hz
|
|
Resolution
|
0.1Hz at 45-99.9Hz , 1Hz at 100-500Hz
|
|
Accuracy
|
±0.02% of setting
|
|
Frequency
|
Range
|
45-1000Hz
|
|
(Option 45Hz-1KHz)
|
Resolution
|
0.1Hz at 45-99.9Hz , 1Hz at 100-1000Hz
|
|
|
Accuracy
|
±0.02% of setting
|
|
Starting& Ending
|
Range
|
0-360°
|
|
Phase Angle
|
Resolution
|
1°
|
|
|
Accuracy
|
±1°(45 - 65HZ)
|
|
MEASUREMENT
|
|
Frequency
|
Range
|
0.0-1000.0Hz
|
|
Resolution
|
0.1Hz
|
|
Accuracy
|
±0.1Hz
|
|
Voltage
|
Range
|
0.0-300.0V / 0.0-600.0V
|
|
Resolution
|
0.1V
|
|
Accuracy
|
± (0.5% of reading +2 counts) for 0-300V
|
|
± (0.5% of reading +4 counts) for 0-600V
|
|
Current(r.m.s)
|
Range
|
L
|
0.000-3.500A
|
|
H
|
3.00-35.00A
|
|
Resolution
|
L
|
0.001A
|
|
H
|
0.01A
|
|
Accuracy
|
L
|
± (0.5% of reading +5 counts) for 0-300V
|
|
± (0.5% of reading +10 counts) for 0-600V
|
|
H
|
± (0.5% of reading +3 counts)
|
|
Current(peak)
|
Range
|
0.0 -200.0A
|
|
Resolution
|
0.1A
|
|
Accuracy
|
± (1% of reading +2 counts)
|
|
Power
|
Range
|
L
|
0.0-350.0W
|
|
H
|
300-4000W
|
|
Resolution
|
L
|
0.1W
|
|
H
|
1W
|
|
Accuracy
|
L
|
± (0.6% of reading +5 counts)
|
|
H
|
± (0.6% of reading +2 counts)
|
|
Power Factor
|
Range
|
0 - 1.000
|
|
Resolution
|
W / VA ,Calculated and displayed to three significant digits
|
|
Accuracy
|
|
GENERAL
|
|
Low Range Meter (for 6705/ 6710 Option)
|
Range : 2.0mA - 350.0mA / 0.20 - 35.00W
|
|
Resolution : 0.1mA / 0.01W
|
|
Accuracy : ± (0.6% of reading +5 counts).
|
|
Remote Input Signal(Option)
|
Test, Reset, Recall program memory 1 through 7
|
|
Remote Output Signal
|
Pass, Fail , Test-in Process
|
|
Memory
|
50 memories, 9 steps/memory
|
|
Sync Output Signal
|
Output Signal 10V ,BNC type
|
|
Timer
|
0=Continuous, 0.1-999.9 (Unit: sec, minute, hour selectable)
|
|
Alarm Volume Setting
|
Range: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume.
|
|
Graphic Display
|
240 x 64 dot resolution Monographic LCD /Contrast 9 Levels 1-9
|
|
Auto loop cycle
|
By step or memory, or system loop cycle setting. 0=Continuous, OFF, 2~9999
|
|
Over Current Fold Back
|
On/Off , Setting On when output current over setting A-Hi value it will fold back output voltage to keep constant output current is setting A-Hi value.
|
|
Protection
|
OCP, OTP ,OVP and Alarm
|
|
Interface
|
GPIB / RS232 / Remote I/P Control option
|
|
Dimension(WxHxD) mm
|
430 x 89 x 400, 2U
|
430 x 89 x 560, 2U
|
430 x 267 x 650, 6U
|
430 x 667 x 650, 15U
|
430 x 667 x 650, 15U
|
|
Net Weight
|
25Kg
|
36Kg
|
90Kg
|
165Kg
|
192Kg
|
|
Operation Environment
|
0-40°C/20-80%RH
|